⿎ Setting request data : When deleting point setting
Start
PRD
code
⿎ Data description
Name
Object No.
Point No.
(First point No. to delete)
Setting/Deleting
Last point No. to delete
Total data length
* Setting request data are variable length.
⿎ Data example
Condition:
Object No. = 1, Point No. = 5, Setting/Deleting = 0, Last point No. to delete = 10
• Setting
Transmission data
Reference
• If you want to delete all point elements, it is also possible to use DEL (object deletion) command to eliminate the point
radiation object.
118
[Object No.], [Point No.],
S
[Setting/Deleting], [Last point No. to delete]
Data
Omit
length
[byte]
Max. 4*
"0000"–"1999"
Max. 2*
"00"–"49"
1
"0": Deleting
Y
Max. 2*
"00"–"49"
Max. 12
It is the length including the separator ",".
[STX]
PRD
Max. 12-byte
Data content
• Specify the point no. to delete.
• To delete two or more points, this number is
the start point number to delete.
• Specify the smaller no. to the first point no.
than the last point no.
To delete the radiation point, specify "0".
• Deletes all points from the specified first
point no. to the last point no.
• To delete the only one point, omit the last
point no. or specify the same no. to the first
and last point no.
• This command is accepted even if there is
no setting in the specified point no.
S
1,5,0,10
[CR]
ME-LPGS-SR-5
(Check sum)
End code
Remarks