Siemens SINAMICS G115D Operating Instructions Manual page 294

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Data backup and series commissioning
7.5 Know-how protection
Function description
The active know-how protection provides the following:
• With just a few exceptions, the values of all adjustable parameters p ... are invisible.
– Several adjustable parameters can be read and changed when know-how protection is
– Several adjustable parameters can be read but not changed when know-how
• The values of monitoring parameters r ... remain visible.
• Adjustable parameters cannot be changed using commissioning tools.
• Locked functions:
– Downloading converter settings using Startdrive
– Automatic controller optimization
– Stationary or rotating measurement of the motor data identification
– Deleting the alarm history and the fault history
– Generating acceptance documents for safety functions
• Executable functions:
– Restoring factory settings
– Acknowledging faults
– Displaying faults, alarms, fault history, and alarm history
– Reading out the diagnostic buffer
– Controlling the converter via Startdrive
– Uploading adjustable parameters that can be changed or read when know-how
– Displaying acceptance documents for safety functions
When know-how protection is active, support can only be provided (from Technical Support)
after prior agreement from the machine manufacturer (OEM).
Know-how protection without copy protection
You can transfer converter settings to other converters using a memory card or Startdrive.
Know-how protection with basic copy protection
After replacing a converter, to be able to operate the new converter with the settings of the
replaced converter without knowing the password, the memory card must be inserted in the
new converter.
292
active. You can find a list of the adjustable parameters that can be read and changed in
the List Manual under "KHP_WRITE_NO_LOCK".
In addition, you can define an exception list of adjustable parameters, which end users
may change.
protection is active. You can find a list of the adjustable parameters that can be read in
the List Manual under "KHP_ACTIVE_READ".
protection is active.
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B