Motor Holding Brake - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameters
Parameter
p0010
r0050.0...1
p0170
p0809[0...2]
p0810
p0811
6.10

Motor holding brake

Overview
The motor holding brake holds the motor in position when it is switched off.
When the "Motor holding brake" function is correctly set, the motor remains switched on as
long as the motor holding brake is open. The converter only switches the motor off when the
motor holding brake is closed.
Function description
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Description
Drive commissioning parameter
filter
CO/BO: Command Data Set CDS
effective
Number of command data sets
(CDS)
Copy command data set CDS
BI: Command data set selection
CDS bit 0
BI: Command data set selection
CDS bit 1
Advanced commissioning
6.10 Motor holding brake
Setting
Set p0010 = 15 to change the data set.
Factory setting: 1
Displays the number of the currently active com-
mand data set
p0170 = 2, 3 or 4
Factory setting: 2
[0] Source command data set
[1] Target command data set
[2] 0→1: Starts the copy operation
Factory setting: 0
Sets the signal source to select CDS bit 0.
Factory setting: dependent upon the converter
Sets the signal source to select CDS bit 1.
Factory setting: 0
179