Mounting

3.2 Mounting the G115D Wall Mounted drive

Dimensions of the geared motor
For further information on the dimensions of the geared motors, refer to the following
documentation:
• The relevant chapter in this manual
• The relevant catalog
• Drive Technology Configurator (DT Configurator)
You can generate and download data sheets, 2D dimension drawings and 3D CAD models
of the geared motors.
3.2
Mounting the G115D Wall Mounted drive
Mounting the converter
You must mount the converter on a metal backplane or on a frame which allows air flow
from the back.
Mounting orientations
The converter supports the following mounting orientations: correct (✓); permissible with
restrictions (!)
The permissible output current is reduced for mounting orientations ① ~ ④.
②③④
38
Additional information on the SIMOGEAR geared motor (Page 353)
Catalog D 31.2 (https://support.industry.siemens.com/cs/ww/en/view/109750324)
DT Configurator (http://www.siemens.com/dt-configurator)
Derating the output current to 80% of the rated converter current is necessary.
Derating the output current to 70% of the rated converter current is necessary.
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B