Additional information on the SIMOGEAR geared motor
11.2 Specific data motor
Table 11- 27 Explanation
1st position
2nd position
3rd position
4th position
Modular structure of the circuit diagrams
The circuit diagrams have a modular structure and have been simplified.
Table 11- 28 Structure of the circuit diagrams
Supple-
Terminal
mentary
marking
device
Europe
Europe
1BD
1BD1; 1BD2
1BA
1BA1; 1BA2
1S
1S1; 1S2
1R
1R1; 1R2
7R
7R1; 7R2.1;
7R2.2
398
Identification letter for circuit diagrams.
Marking for the connection type:
0: Standard connection at the terminal board (motor), terminal block (auxiliary
connections).
1: Standard connection at the connector box.
Identification for the circuit diagram content.
Consecutive number for additional versions.
Supple-
Terminal
mentary
marking
device
Nema
Nema
B
B1; B2
B
B3; B4
B
B5; B6
P
P27; P28
P
P29; P30.1;
P30.2
Terminal
Designation
numbering
05; 06
Brake control
07; 08
Brake control
09; 10
Brake control
95; 96
Temperature monitor
motor winding
97; 98.1;
Temperature monitor
98.2
gearbox
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Function
DC connection, brake
AC voltage connection,
brake rectifier
Jumper, DC circuit, brake
rectifier
Resistance thermometer
Pt1000
Resistance thermometer
1 Pt100 oil sensor