Connecting The 24 V Power Supply; Interface Description - X01/X02 - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Wiring

4.11 Connecting the 24 V power supply

4.11
Connecting the 24 V power supply
Electric shock due to unsuitable power supply
When equipment is connected to an unsuitable power supply, exposed components may
carry a hazardous voltage that might result in serious injury or death.
• Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV-
4.11.1

Interface description - X01/X02

Connector variant
One of the two types of connectors (7/8" and M12 L-coding) is provided depending on the
variant that has been ordered.
7/8" connector
X01 - 24 V power supply
(IN), 5-pin, male
M12 L-coding connector
X01 - 24 V power supply
(IN), 5-pin, male
68
WARNING
(Protective Extra Low Voltage) output voltages (maximum 60 V DC briefly) for all
connections and terminals of the electronics modules.
X02 - 24 V power supply
(OUT), 5-pin, female
X02 - 24 V power supply
(OUT), 5-pin, female
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Pin
Signal
Description
1
2M
Switched 0 V
2
1M
Unswitched 0 V
3
FE
Not connected
4
1L+
Unswitched 24 V
5
2L+
Switched 24 V
Pin
Signal
Description
1
1L+
Unswitched 24 V
2
2M
Switched 0 V
3
1M
Unswitched 0 V
4
2L+
Switched 24 V
-
FE
Not connected
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading

Table of Contents