General Technical Description - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
11.2 Specific data motor
The motors have been designed for the application described in Section Technical data
(Page 365). Do not operate the motor outside the specified power limit. Other operating
conditions must be contractually agreed.
Never use degrees of protection ≤ IP54 outdoors. Air-cooled versions are designed for
ambient temperatures of -15 °C to +40 °C as standard and for an installation altitude of up to
1 000 m above sea level. Please note any deviations to the data on the rating plate.
Conditions at the location of use must comply with all specifications on the rating plate.
Do not climb on the motor. Do not place any objects on the motor.
11.2.3

General technical description

The motor complies with the following regulations:
Table 11- 10 Overview of the standards
Feature
Dimensioning and operational behavior
Degree of protection
Cooling
Mounting position according to modular system
Terminal marking and direction of rotation
Noise emission
Thermal protection
Starting characteristics, rotating electric motors
Vibration severity levels
IEC standard voltages
Safety of machinery
The motor is equipped with grease-lubricated roller bearings. The bearings are permanently
lubricated.
The stator winding is designed for temperature class 155 (F).
In the standard version, the rotor has vibration severity level A.
The technical data for the optional monitoring equipment can be viewed in the circuit
diagrams, on the rating plate or in the special order documents.
The stator housing and bearing shields are made of die-cast aluminum or cast iron.
The surface of the stator housing is equipped with cooling ribs and a mounted terminal box
or motor connector.
374
Standard
EN 60034-1
EN 60034-5
EN 60034-6
EN 60034-7
EN 60034-8
EN 60034-9
EN 60034-11
EN 60034-12
EN 60034-14
IEC 60038
EN 60204-1
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading