6.8.2.3

Turntable, three positions and one speed (p3393 = 7)

Overview
With p3393 (conveyor technology application) set to 7, the converter enables a turntable in a
conveyor system to rotate in either positive or negative direction with a fixed speed and stop
at three dedicated positions. Three sensors are required to signal the limit positions for the
motor to stop.
Precondition
• You interconnect the signals of the sensors with the digital inputs of your choice.
• Depending on the specific application and mechanical setup, you must set end position
shutdown active (p3392) to 1, so as to limit the turntable movement between the
dedicated positions.
Function description
• With the ON command, the motor accelerates to its speed setpoint (p1070). The turntable
can rotate in either positive or negative direction depending on the setting of p1113:
– p1113 = 0: positive direction
– p1113 = 1: negative direction
• With the end position shutdown deactivated (p3392 = 0), the following applies:
– The motor stops with OFF1 ramp when any of the three stop sensors (p3384, p3385,
– With the sensor evaluation type (p3394) set to 1 or 2 (level triggering), the motor
– Setting the sensor bypass signal (p3390) to 1 overrides the sensor signals p3384,
• With the end position shutdown activated (p3392 = 1), the following applies:
– If the motor runs in positive direction, it stops only when the stop sensor center
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
and p3386) is triggered (level/edge triggered depending on p3394).
starts again in either positive or negative direction when the level is canceled; with
p3394 set to 3 or 4 (edge triggering), a new ON command must be initiated to start
the motor again in either positive or negative direction.
p3385, and p3386.
(p3386) or stop sensor positive direction (p3384) is triggered.