Fundamental safety instructions
1.1 General safety instructions
Risk of electric shock and fire from supply networks with an excessively low
impedance
Excessively high short-circuit currents can lead to the protective devices not being able to
interrupt these short-circuit currents and being destroyed, and thus causing electric shock or
a fire.
• Ensure that the prospective short-circuit current at the line terminal of the converter
Electric shock if there is no ground connection
For missing or incorrectly implemented protective conductor connection for devices with
protection class I, high voltages can be present at open, exposed parts, which when
touched, can result in death or severe injury.
• Ground the device in compliance with the applicable regulations.
Electric shock due to connection to an unsuitable power supply
When equipment is connected to an unsuitable power supply, exposed components may
carry a hazardous voltage. Contact with hazardous voltage can result in severe injury or
death.
• Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV-
Electric shock due to damaged motors or devices
Improper handling of motors or devices can damage them.
Hazardous voltages can be present at the enclosure or at exposed components on damaged
motors or devices.
• Ensure compliance with the limit values specified in the technical data during transport,
• Do not use any damaged motors or devices.
Electric shock due to unconnected cable shield
Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected
cable shields.
• Attach the cable shields at least on one side to the grounded housing potential.
16
WARNING
does not exceed the breaking capacity (SCCR or Icc) of the protective device used.
WARNING
WARNING
(Protective Extra Low Voltage) output voltages for all connections and terminals of the
electronics modules.
WARNING
storage and operation.
WARNING