Advanced commissioning
6.18 Electrically braking the motor
6.18.2

Dynamic braking

Typical applications for dynamic braking require continuous braking and acceleration
operations or frequent changes of the motor direction of rotation:
• Horizontal conveyors
• Vertical and inclined conveyors
• Hoisting gear
Principle of operation
The DC link voltage increases as soon as the motor supplies regenerative power to the
converter when braking. Depending on the DC link voltage, the converter outputs the
regenerative power to the integrated braking resistor. The built-in braking resistor converts
the regenerative power into heat, therefore preventing DC link voltages > Vdc_max.