[Pr. Pb77_Vibration Suppression Control 2 - Vibration Frequency Damping After Gain Switching 2 (Vrf23C)]; [Pr. Pb78_Vibration Suppression Control 2 - Resonance Frequency Damping After Gain Switching 2 (Vrf24C)]; [Pr. Pb79_Gain Switching 2 - Model Control Gain (Pg1C)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

[Pr. PB77_Vibration suppression control 2 - Vibration frequency
damping after gain switching 2 (VRF23C)]
Initial value
0.00
Set the damping of the vibration frequency for vibration suppression control 2 for when the gain switching is enabled.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PA24.0 Vibration suppression mode selection] is set to "1" (3 inertia mode).
• [Pr. PB02.1 Vibration suppression control 2 - Tuning mode selection] is set to "2" (manual setting).
• [Pr. PB26.0 Gain switching selection] is set to "1" (signal (CDP)), and [Pr. PB26.4 Gain switching 2 selection] is set to "2"
(the same condition as [Pr. PB26.0 Gain switching selection]). Or, "1" (signal (CDP2)) is selected in [Pr. PB26.4].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB78_Vibration suppression control 2 - Resonance
frequency damping after gain switching 2 (VRF24C)]
Initial value
0.00
Set the damping of the resonance frequency for vibration suppression control 2 for when the gain switching is enabled.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PA24.0 Vibration suppression mode selection] is set to "1" (3 inertia mode).
• [Pr. PB02.1 Vibration suppression control 2 - Tuning mode selection] is set to "2" (manual setting).
• [Pr. PB26.0 Gain switching selection] is set to "1" (signal (CDP)), and [Pr. PB26.4 Gain switching 2 selection] is set to "2"
(the same condition as [Pr. PB26.0 Gain switching selection]). Or, "1" (signal (CDP2)) is selected in [Pr. PB26.4].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.

[Pr. PB79_Gain switching 2 - Model control gain (PG1C)]

Initial value
0.0 [rad/s]
Set the model control gain for when the gain switching is enabled.
When the setting value of this servo parameter is less than "1.0", the setting value of [Pr. PB07 Model control gain] is applied.
This servo parameter is enabled in the following conditions:
• [Pr. PB26.0 Gain switching selection] is set to "1" (signal (CDP)), and [Pr. PB26.4 Gain switching 2 selection] is set to "2"
(the same condition as [Pr. PB26.0 Gain switching selection]). Or, "1" (signal (CDP2)) is selected in [Pr. PB26.4].
1 SERVO PARAMETER DETAILS
58
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Setting range
0.00 to 0.30
Setting range
0.00 to 0.30
Setting range
0.0 to 8000.0
Ver.
A0
Ver.
A0
Ver.
A0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5-aMr-j5-a-rjMelservo-j5

Table of Contents