[Pr. Pb33_Vibration Suppression Control 1 - Vibration Frequency After Gain Switching (Vrf11B)]; [Pr. Pb34_Vibration Suppression Control 1 - Resonance Frequency After Gain Switching (Vrf12B)]; [Pr. Pb35_Vibration Suppression Control 1 - Vibration Frequency Damping After Gain Switching (Vrf13B)]; [Pr. Pb36_Vibration Suppression Control 1 - Resonance Frequency Damping After Gain Switching (Vrf14B)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

[Pr. PB33_Vibration suppression control 1 - Vibration frequency
after gain switching (VRF11B)]
Initial value
0.0 [Hz]
Set the vibration frequency of vibration suppression control 1 for when the gain switching is enabled.
When the setting value of this servo parameter is less than "0.1", the setting value of [Pr. PB19 Vibration suppression control
1 - Vibration frequency] is applied.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB34_Vibration suppression control 1 - Resonance
frequency after gain switching (VRF12B)]
Initial value
0.0 [Hz]
Set the resonance frequency for vibration suppression control 1 for when the gain switching is enabled.
When the setting value of this servo parameter is less than "0.1", the setting value of [Pr. PB20 Vibration suppression control
1 - Resonance frequency] is applied.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB35_Vibration suppression control 1 - Vibration frequency
damping after gain switching (VRF13B)]
Initial value
0.00
Set the damping of the vibration frequency for vibration suppression control 1 for when the gain switching is enabled.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB36_Vibration suppression control 1 - Resonance
frequency damping after gain switching (VRF14B)]
Initial value
0.00
Set the damping of the resonance frequency for vibration suppression control 1 for when the gain switching is enabled.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
1 SERVO PARAMETER DETAILS
46
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Setting range
0.0 to 300.0
Setting range
0.0 to 300.0
Setting range
0.00 to 0.30
Setting range
0.00 to 0.30
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
A0