[Pr. PA02_Regenerative option (**REG)]

Initial value
00000000h
[Pr. PA02.0-1_Regenerative option selection]
Initial value
00h
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
Other regenerative options cannot be used together with the FR-XC.
If a selected regenerative option is not for use with the servo amplifier, [AL. 037 Parameter error] occurs.
00: Regenerative option is not used.
• No regenerative resistors are used on servo amplifiers with a capacity of 100 W.
• Built-in regenerative resistors are used on servo amplifiers with a capacity of 0.2 kW to 7 kW.
01: FR-XC
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
08: MR-RB31
09: MR-RB51 (A cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (A cooling fan is required.)
0D: MR-RB14
0E: MR-RB34
[Pr. PA02.4_Simple converter selection]
Initial value
0h
When using the simple converter, set this servo parameter.
The simple converter and external regenerative option can be used together. When using an external regenerative option, set
the regenerative option to be used with [Pr. PA02.0-1].
When [Pr. PA02.0-1 Regenerative option selection] is set to "01" (FR-XC), setting this servo parameter to "1" (enabled)
triggers [AL. 037 Parameter error].
0: Simple converter is not used
1: MR-CM3K
[Pr. PA02.5_Excessive regeneration warning enabled/disabled selection]
Initial value
0h
When the simple converter is used, whether to enable or disable the detection of [AL. 0E0.1 Excessive regeneration warning]
is selectable with this servo parameter.
When [Pr. PA02.4] is set to "0" (simple converter is not used), setting this servo parameter to "1" (disabled) triggers [AL. 037
Parameter error].
0: Enabled
1: Disabled
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text