[Pr. PD30_Function selection D-1 (*DOP1)]

Initial value
00000000h
Set the following: the stop processing method at LSP/LSN signal off, the status of the base circuit when the RES signal is
shorted, and the enable/disable setting of the servo motor thermistor.
[Pr. PD30.0_Stop processing selection at LSP/LSN signal OFF]
Initial value
0h
Select the stop processing method at LSP/LSN signal off.
0: Quick stop
1: Slow stop
[Pr. PD30.1_Base circuit status selection for RES (Reset) on]
Initial value
0h
0: Base circuit shut-off
1: Base circuit not shut-off
[Pr. PD30.3_Servo motor thermistor - Enabled/disabled selection]
Initial value
0h
0: Enabled
1: Disabled
This servo parameter is enabled when a servo motor with a built-in thermistor is used. When a servo motor without a
thermistor is used, the servo parameter is disabled (temperature monitoring disabled/alarm disabled) regardless of the setting
value.
No alarm is detected in motor-less operation.
When the temperature monitoring of the motor thermistor is disabled, "9999 °C" is displayed.
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0
Ver.
A0
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
1
97