[Pr. Pc31_Speed Deceleration Time Constant 2 (Stb2)]; [Pr. Pc32_Command Input Pulse Multiplication Numerator 2 (Cmx2)]; [Pr. Pc33_Command Input Pulse Multiplication Numerator 3 (Cmx3)]; [Pr. Pc34_Command Input Pulse Multiplication Numerator 4 (Cmx4)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

[Pr. PC31_Speed deceleration time constant 2 (STB2)]

Initial value
0 [ms]
In the speed control mode or torque control mode, set the deceleration time for the servo motor to stop from the rated speed
for the analog speed command and internal speed command.
When STAB2 (Second acceleration/deceleration selection) is turned on, the setting value of this servo parameter is enabled.
Set the deceleration time required to reach 0 r/min from the rated speed for VC (Analog speed command) and [Pr. PC05
Internal speed 1] to [Pr. PC11 Internal speed 7].
[Pr. PC32_Command input pulse multiplication numerator 2
(CMX2)]
Initial value
1
Set the multiplication factor for command input pulses.
This servo parameter is enabled when [Pr. PA21.3 Electronic gear compatibility selection] is set to "0", "2", "3", or "4".
CM1
Open
Shorted
Open
Shorted
[Pr. PC33_Command input pulse multiplication numerator 3
(CMX3)]
Initial value
1
Set the multiplication factor for command input pulses.
This servo parameter is enabled when [Pr. PA21.3 Electronic gear compatibility selection] is set to "0", "2", "3", or "4".
[Pr. PC34_Command input pulse multiplication numerator 4
(CMX4)]
Initial value
1
Set the multiplication factor for command input pulses.
This servo parameter is enabled when [Pr. PA21.3 Electronic gear compatibility selection] is set to "0", "2", "3", or "4".

[Pr. PC35_Internal torque limit 2 (TL2)]

Initial value
1000.0 [%]
Set the servo parameter for limiting the torque or thrust generated by the servo motor assuming the rated torque or
continuous thrust as 100.0 %. If this servo parameter is set to "0.0", the servo motor does not generate torque or thrust.
If TL1 (Internal torque limit selection) is turned on, the setting value of [Pr. PA11] or [Pr. PA12] is compared with [Pr. PC35
Internal torque limit 2] and the lower one will be enabled.
When [Pr. PC50.0 Torque limit unit change] is set to "0" (maximum torque unit), set the servo parameter in relation to the
maximum torque or maximum thrust (= 100.0 %).
Setting range
0 to 50000
Setting range
1 to 2147483647
CM2
Open
Open
Shorted
Shorted
Setting range
1 to 2147483647
Setting range
1 to 2147483647
Setting range
0.0 to 1000.0
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Ver.
A0
Ver.
A0
Electronic gear
CMX
CMX2
CMX3
CMX4
Ver.
A0
Ver.
A0
Ver.
A0