[Pr. Pf87_Drive Recorder - Analog Channel Setting 1 (Drac1)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

[Pr. PF87_Drive recorder - Analog channel setting 1 (DRAC1)]

Initial value
00020201h
[Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
Initial value
201h
Select the data to be assigned to analog channel 1 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] = "0" (automatic setting mode)
Refer to the following table for setting values.
Values not listed below are undefined. Only set the values that are listed in the following table.
Setting value
Data type
000
No assigned function
001
Servo motor speed
002
Torque/instantaneous torque
003
Current command
004
Command pulse frequency
005
Command pulse frequency (speed unit)
007
Droop pulses (1 pulse unit)
008
Speed command
009
Bus voltage
00C
Effective load ratio
00D
Regenerative load ratio
00E
Position within one-revolution
00F
ABS counter
010
Load to motor inertia ratio
011
Torque equivalent to disturbance
012
Overload alarm margin
014
Settling time
015
Overshoot amount
*2
01C
Load-side encoder droop pulses (1 pulse unit)
*2
01E
Motor-side/load-side position deviation (1 pulse unit)
*2
020
Motor-side/load-side speed deviation
021
Servo motor speed (unit of 0.1 r/min)
022
Command pulse frequency (speed unit of 0.1 r/min)
023
Speed command (unit of 0.1 r/min)
024
Torque command
025
Speed limit value
026
Speed limit value (unit of 0.1 r/min)
035
Internal temperature of encoder
03B
Load-side encoder information 1
03C
Load-side encoder information 2
049
Operation mode
*3
04C
U-phase current feedback (unit of the rated current)
*3
04D
V-phase current feedback (unit of the rated current)
*3
04E
W-phase current feedback (unit of the rated current)
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A0
*1
Unit
Category
1 r/min
16-bit data
0.1 %
0.1 %
kpulse/s
1 r/min
1 pulse
1 r/min
1 V
0.1 %
0.1 %
16 pulses
1 rev
0.01 multiplier
0.1 %
0.1 %
1 ms
1 pulse
1 pulse
1 pulse
1 r/min
0.1 r/min
0.1 r/min
0.1 r/min
0.1 %
1 r/min
0.1 r/min
1 °C
16 pulses
1 rev
1LSB
0.1 %
0.1 %
0.1 %
1 SERVO PARAMETER DETAILS
1
127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5-aMr-j5-a-rjMelservo-j5

Table of Contents