Mitsubishi Electric MELSERVO-J5 Series User Manual page 126

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

[Pr. PF82.1_Drive recorder - Trigger binding condition selection]
Initial value
0h
Select the trigger binding condition for the drive recorder.
When this servo parameter is set to "0" (disabled), the settings of [PF84.2-3 Drive recorder - Trigger channel selection 2] and
[PF86 Drive recorder - Trigger level setting 2] are disabled.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger), the setting value of this servo
parameter is disabled.
0: Disabled
1: Logical AND of trigger signals
2: Logical OR of trigger signals
[Pr. PF82.2_Drive recorder - Trigger operation selection 1]
Initial value
0h
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.0-1 Drive recorder -
Trigger channel selection 1] exceeds or falls below the set trigger level.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0] is set to "0" (alarm trigger), the setting value of this servo parameter is disabled.
0: Rising
1: Falling
[Pr. PF82.3_Drive recorder - Trigger operation selection 2]
Initial value
0h
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.2-3 Drive recorder -
Trigger channel selection 2] exceeds or falls below the set trigger level.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
• [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger)
• [Pr. PF82.1 Drive recorder - Trigger binding condition selection] is set to "0" (disabled)
0: Rising
1: Falling
1 SERVO PARAMETER DETAILS
124
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
Ver.
A0
Ver.
A0
Ver.
A0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5-aMr-j5-a-rjMelservo-j5

Table of Contents