[Pr. PD07_Input device selection 3L (*DI3L)]

Initial value
00000704h
Select the device to be assigned to the input signal of the CN3-17 pin.
If the absolute position detection system with DIO is selected while [Pr. PA03.0 Absolute position detection system selection]
has been set to "1" (enabled (absolute position detection system by DIO)), the CN3-17 pin becomes ABSM (ABS transfer
mode).
[Pr. PD07.0-1_Position control mode - Device selection]
Initial value
04h
Refer to the following for setting values.
Page 87 [Pr. PD03_Input device selection 1L (*DI1L)]
[Pr. PD07.2-3_Speed control mode - Device selection]
Initial value
07h
Refer to the following for setting values.
Page 87 [Pr. PD03_Input device selection 1L (*DI1L)]

[Pr. PD08_Input device selection 3H (*DI3H)]

Initial value
00000707h
Select the device to be assigned to the input signal of the CN3-17 pin.
If the absolute position detection system with DIO is selected while [Pr. PA03.0 Absolute position detection system selection]
has been set to "1" (enabled (absolute position detection system by DIO)), the CN3-17 pin becomes ABSM (ABS transfer
mode).
[Pr. PD08.0-1_Torque control mode - Device selection]
Initial value
07h
Refer to the following for setting values.
Page 87 [Pr. PD03_Input device selection 1L (*DI1L)]
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0
Ver.
Refer to the relevant detail No.
Ver.
A0
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])