[Pr. PF75_Static friction when extended (ASF)]

Initial value
0 [0.1 %]
Set a static friction for when the belt stretches or for when the belt is looser than at the time of the attachment. Set the static
friction with any of the following values estimated by the friction estimation function depending on the value of [Pr. PF71.1 Belt
tension deterioration prediction friction selection]: static friction at forward rotation, static friction at reverse rotation, or the
average of the estimated frictions.
The belt tension deterioration prediction function is disabled when the setting is: [Pr. PF74 Static friction during installation] <
[Pr. PF75 Static friction when extended].

[Pr. PF76_Belt tension irregular threshold (BTS)]

Initial value
0 [0.1 %]
Set a threshold to generate [AL. 0F7 Machine diagnosis warning]. Set this servo parameter as a percentage of [Pr. PF72 Belt
tension on installation]. When using the belt diagnosis function, input a value other than "0".
[Pr. PF72 Belt tension
on installation]
[Pr. PF73 Belt tension
when extended]
Belt tension threshold
Static friction that triggers a warning
Belt tension threshold = [Pr. PF76 Belt tension irregular threshold]/100 × [Pr. PF72 Belt tension on installation]
Setting range
0 to 10000
Setting range
0 to 1000
[Pr. PF74 Static friction during installation]
[Pr. PF75 Static friction when extended]
Ver.
A0
Ver.
A0