1.8
Motor extension setting servo parameters group
([Pr. PL_ _ ])

[Pr. PL01_Function selection L-1 (**LIT1)]

Initial value
00000301h
Select a function of the linear servo motor or direct drive motor.
[Pr. PL01.0_Servo motor magnetic pole detection selection]
Initial value
1h
Select the magnetic pole detection method for the linear servo motor or direct drive motor.
0: Magnetic pole detection disabled
1: Magnetic pole detection at initial servo-on after cycling the power
5: Magnetic pole detection at every servo-on
The setting value "0" is enabled on absolute position linear encoders.
Do not set any value other than "0", "1", and "5".
[Pr. PL01.2_Homing stop interval setting]
Initial value
3h
Select the stop interval at dog type homing.
This servo parameter is enabled only for linear servo motors.
13
0: 2
(= 8192) pulses
17
1: 2
(= 131072) pulses
18
2: 2
(= 262144) pulses
20
3: 2
(= 1048576) pulses
22
4: 2
(= 4194304) pulses
24
5: 2
(= 16777216) pulses
26
6: 2
(= 67108864) pulses

[Pr. PL02_Linear encoder resolution setting - Numerator (**LIM)]

Initial value
1000 [μm]
Set the linear encoder resolution with [Pr. PL02] and [Pr. PL03].
Set a numerator in [Pr. PL02].
This servo parameter is enabled for linear servo motors.
[Pr. PL03_Linear encoder resolution setting - Denominator
(**LID)]
Initial value
1000 [μm]
Set the linear encoder resolution with [Pr. PL02] and [Pr. PL03].
Set a denominator in [Pr. PL03].
This servo parameter is enabled for linear servo motors.
1 SERVO PARAMETER DETAILS
134

1.8 Motor extension setting servo parameters group ([Pr. PL_ _ ])

Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
1 to 65535
Setting range
1 to 65535
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
A0