[Pr. PC27_Function selection C-6 (*COP6)]

Initial value
00000000h
[Pr. PC27.2_Undervoltage alarm selection]
Initial value
0h
Select the alarm or warning that occurs when the bus voltage drops to the undervoltage alarm trigger level.
0: [AL. 010 Undervoltage] occurs regardless of servo motor speed
1: [AL. 0E9 Main circuit off warning] occurs when the servo motor speed is 50 r/min (50 mm/s) or less, and [AL. 010] occurs
when over 50 r/min (50 mm/s).
[Pr. PC27.4_Input open-phase detection selection]
Initial value
0h
Enable or disable the detection of input open-phase detection function.
0: Automatic
1: Warning enabled
2: Alarm enabled
3: Disabled
The following table shows the input open-phase detection function for when "0" (automatic) is set.
Servo amplifier main circuit input voltage
3-phase AC
1-phase AC
Main circuit DC
3-phase AC
Main circuit DC

[Pr. PC28_Function selection C-7 (*COP7)]

Initial value
00000000h
[Pr. PC28.3_Linear encoder multipoint Z-phase input - Function selection]
Initial value
0h
When multiple reference marks exist during the full stroke of the linear encoder, set "1".
0: Disabled
1: Enabled
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Amplifier capacity
2 [kW] or less
2 [kW] or less
3.5 [kW] or more
3.5 [kW] or more
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0
Input open-phase detection function
Disabled
Disabled
Warning occurrence
Disabled
Ver.
Refer to the relevant detail No.
Ver.
A0
1 SERVO PARAMETER DETAILS
1
73