[Pr. PC24_Function selection C-3 (*COP3)]

Initial value
00000000h
[Pr. PC24.0_In-position range unit selection]
Initial value
0h
Select a unit of the in-position range.
If [Pr. PA01.4 Fully closed loop operation mode selection] is set to "1" (fully closed loop system), the in-position range is in the
load-side encoder pulse unit.
0: Command input pulse unit
1: Servo motor encoder pulse unit
[Pr. PC24.3_Excessive error alarm trigger level/excessive error warning trigger level -
Unit selection]
Initial value
0h
Select the unit used when setting the excessive error alarm trigger level in [Pr. PC43 Excessive error alarm trigger level] and
setting the excessive error warning trigger level in [Pr. PC73 Excessive error warning trigger level].
0: [rev] or [mm]
1: [0.1 rev] or [0.1 mm]
2: [0.01 rev] or [0.01 mm]
3: [0.001 rev] or [0.001 mm]
This setting value is enabled in the position mode.
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0
1 SERVO PARAMETER DETAILS
1
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5-aMr-j5-a-rjMelservo-j5

Table of Contents