Mitsubishi Electric MELSEC iQ-R Series User Manual page 214

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
3176 or later
System area
(C68H or
later)
*1 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Heating-cooling control (expanded
mode) (2). When Heating-cooling control (normal mode) (1) is set, this area becomes a system area.
*2 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Heating-cooling control (normal
mode) (1). When Heating-cooling control (expanded mode) (2) is set, this area becomes a system area.
*3 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Mix control (expanded mode) (4).
When Mix control (normal mode) (3) is set, this area becomes a system area.
*4 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Mix control (normal mode) (3).
When Mix control (expanded mode) (4) is set, this area becomes a system area.
*5 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Position-proportional control
(expanded mode) (6). When Position-proportional control (normal mode) (5) is set, this area becomes a system area.
*6 Enabled only when 'Control mode selection' (in the Q compatible mode) (Un\G1025) has been set to Position-proportional control
(normal mode) (5). When Position-proportional control (expanded mode) (6) is set, this area becomes a system area.
*7 [n] in this table indicates an interrupt setting value. (n = 1 to 16)
*8 This value is displayed only in the master module of the inter-module simultaneous temperature rise function. When multiple master
modules have been set, 0 is stored in this area.
*9 This value is displayed only in the master module of the inter-module peak current suppression function. When multiple master modules
have been set, 0 is stored in this area.
*10 This setting differs depending on whether Setting variation rate limiter setting (in the Q compatible mode) (Un\G1024, b1) is set to
Individually set at temperature rise/temperature drop (1).
*11 Enabled only when the R60TCTRT2TT2BW or R60TCRT4BW is used.
*12 Enabled only when the R60TCTRT2TT2 or R60TCTRT2TT2BW is used.
*13 Enabled only when Setting variation rate limiter setting (in the Q compatible mode) (Un\G1024, b1) has been set to Individually set at
temperature rise/temperature drop (1).
*14 Automatic setting at input range change, setting variation rate limiter setting, control output cycle unit, and moving average processing
setting can be configured.
*15 When the control output cycle unit selection setting is 1s cycle
*16 When the control output cycle unit selection setting is 0.1s cycle
APPX
212
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
Default
value
Position-
proportional
control
Data
(1)
(2)
(3)
(4)
type
(5)