Mitsubishi Electric MELSEC iQ-R Series User Manual page 210

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
1080(438H)
CH3
Feed forward
value tuning
selection
1081(439H)
CH3
Auto tuning error
judgment time
1082(43AH)
CH3
Overshoot
suppression
level setting
1083(43BH)
CH3
Heater
disconnection
judgment
mode
1084 to 1087
System area
(43CH to
43FH)
1088(440H)
CH4
System area
1089(441H)
CH4
System area
1090(442H)
CH4
System area
1091(443H)
CH4
System area
1092(444H)
CH4
Disturbance
judgment
position
1093(445H)
CH4
Set value return
adjustment
1094(446H)
CH4
Feed forward
control forced
starting signal
1095(447H)
CH4
Feed forward
value
1096(448H)
CH4
Feed forward
value tuning
selection
1097(449H)
CH4
Auto tuning error
judgment time
1098(44AH)
CH4
Overshoot
suppression
level setting
1099(44BH)
CH4
Heater
disconnection
judgment
mode
1100 to 1199
System area
(44CH to
4AFH)
1200(4B0H)
CH1
Feed forward value memory read command
1201 to 1215
System area
(4B1H to
4BFH)
1216(4C0H)
CH2
Feed forward value memory read
command
APPX
208
Appendix 3 Buffer Memory Areas
Heating-
cooling
control
Feed forward
value tuning
*1
selection
Auto tuning error
*1
judgment time
Overshoot
suppression
*1
level setting
System area
*11
Disturbance
judgment
*1
position
Set value return
*1
adjustment
Feed forward
control forced
*1
starting signal
Feed forward
*1
value
Feed forward
value tuning
*1
selection
Auto tuning error
*1
judgment time
Overshoot
suppression
*1
level setting
System area
*11
Mix control
Position-
proportional
control
Feed forward
System area
value tuning
selection
Auto tuning error
Auto tuning error
judgment time
judgment time
Overshoot
Overshoot
suppression
suppression
*5
level setting
level setting
Heater
System area
disconnection
judgment
*11
mode
Open/close
output neutral
*5
band setting
Control motor
*5
time
Integration
output limiter
*5
setting
Valve operation
setting during
CPU module
*5
STOP
Disturbance
System area
judgment
position
Set value return
System area
adjustment
Feed forward
System area
control forced
starting signal
Feed forward
System area
value
Feed forward
System area
value tuning
selection
Auto tuning error
Auto tuning error
judgment time
judgment time
Overshoot
Overshoot
suppression
suppression
*5
level setting
level setting
Heater
System area
disconnection
judgment
*11
mode
System area
Feed forward
System area
value memory
*3
read command
Default
Data
(1)
value
type
0
Setting
120
Setting
*5
0
Setting
0
Setting
20
Setting
10
Setting
1500
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
120
Setting
*5
0
Setting
0
Setting
0
Control
0
Control
(2)
(3)
(4)
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents