Mitsubishi Electric MELSEC iQ-R Series User Manual page 171

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
264 to 279
All
Condition target channel setting [n]
(108H to
117H)
280 to 299
System area
(118H to
12BH)
300(12CH)
All
Control mode selection
301(12DH)
All
Sampling cycle selection
302(12EH)
All
Automatic setting at input range change
303(12FH)
All
Setting variation rate limiter setting selection
304(130H)
All
Control output cycle unit selection setting
305(131H)
All
Moving average processing setting
306(132H)
All
PID continuation flag
307(133H)
All
Transistor output monitor ON delay time setting
308(134H)
All
Manipulated value resolution change for output with
another analog module
309(135H)
All
Cold junction temperature compensation selection
310 to 399
System area
(136H to
18FH)
400(190H)
CH1
Decimal point position
401(191H)
CH1
Alert definition
402(192H)
CH1
Temperature process value (PV)
403(193H)
CH1
Manipulated
value (MV)
404(194H)
CH1
Temperature rise judgment flag
405(195H)
CH1
Transistor output
flag
406(196H)
CH1
Set value (SV) monitor
407(197H)
CH1
Manipulated
value (MV) for
output with
another analog
module
408(198H)
CH1
System area
409(199H)
CH1
System area
410(19AH)
CH1
System area
411(19BH)
CH1
Self-tuning flag
412(19CH)
CH1
Process value (PV) scaling value
413(19DH)
CH1
AT simultaneous
temperature rise
parameter
calculation flag
414(19EH)
CH1
Simultaneous
temperature rise
status
415(19FH)
CH1
Feed forward control forced start status
416(1A0H)
CH1
Feed forward value tuning flag
417(1A1H)
CH1
Feed forward control READY flag
418(1A2H)
CH1
Feed forward control forced start READY flag
Heating-
Mix control
cooling
control
*10
*1
Manipulated value for heating (MVh)
Heating transistor output flag
Manipulated value for heating (MVh)
for output with another analog
module
Manipulated value for cooling (MVc)
Manipulated value for cooling (MVc)
for output with another analog
module
Cooling transistor output flag
System area
System area
System area
Default
Data
value
type
Position-
proportional
control
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
System area
0
Setting
0
Setting
0
Setting
0
Setting
System area
0
Setting
0
Setting
0(TCTRT)
Monitor
1(TCRT)
0
Monitor
0
Monitor
System area
0
Monitor
0
Monitor
Open side
0
Monitor
transistor output
flag
0
Monitor
System area
0
Monitor
System area
0
Monitor
System area
0
Monitor
Close side
0
Monitor
transistor output
flag
0
Monitor
0
Monitor
0
Monitor
0
Monitor
System area
0
Monitor
System area
0
Monitor
System area
0
Monitor
System area
0
Monitor
Appendix 3 Buffer Memory Areas
(1)
(2)
(3)
(4)
(5)
A
APPX
169