Mitsubishi Electric MELSEC iQ-R Series User Manual page 175

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
610(262H)
CH2
System area
611(263H)
CH2
Self-tuning flag
612(264H)
CH2
Process value (PV) scaling value
613(265H)
CH2
AT simultaneous
temperature rise
parameter
calculation flag
614(266H)
CH2
Simultaneous
temperature rise
status
615(267H)
CH2
Feed forward control forced start
status
616(268H)
CH2
Feed forward value tuning flag
617(269H)
CH2
Feed forward control READY flag
618(26AH)
CH2
Feed forward control forced start READY flag
619(26BH)
CH2
Sensor two-point correction offset latch completion
620(26CH)
CH2
Sensor two-point correction gain latch completion
621 to 629
System area
(26DH to
275H)
630(276H)
CH2
Set value (SV) setting
631(277H)
CH2
Proportional
band (P) setting
632(278H)
CH2
Integral time (I) setting
633(279H)
CH2
Derivative time (D) setting
634(27AH)
CH2
Alert set value 1
635(27BH)
CH2
Alert set value 2
636(27CH)
CH2
Alert set value 3
637(27DH)
CH2
Alert set value 4
638(27EH)
CH2
Temperature process value (PV) for
input with another analog module
639(27FH)
CH2
System area
640(280H)
CH2
Memory's PID constants read
command
Heating-
Mix control
cooling
control
Cooling
Cooling
transistor output
transistor output
*6
flag
flag
System area
Process value
(PV) scaling
*6
value
System area
System area
Feed forward
control forced
*6
start status
Feed forward
value tuning
*6
flag
Set value (SV)
*6
setting
Heating
Heating
proportional
proportional
band (Ph) setting
band (Ph)
*6
setting
Integral time (I)
*6
setting
Derivative time
*6
(D) setting
Alert set value
*6
1
Alert set value
*6
2
Alert set value
*6
3
Alert set value
*6
4
Temperature
process value
(PV) for input
with another
*6
analog module
Cooling
Cooling
proportional
proportional
band (Pc) setting
band (Pc)
*6
setting
Memory's PID
constants read
*6
command
Default
Data
value
type
Position-
proportional
control
Close side
0
Monitor
transistor output
flag
0
Monitor
Process value
0
Monitor
(PV) scaling
value
0
Monitor
0
Monitor
System area
0
Monitor
System area
0
Monitor
System area
0
Monitor
System area
0
Monitor
0
Monitor
0
Monitor
Set value (SV)
0
Control
setting
Proportional
30
Control
band (P) setting
Integral time (I)
240
Control
setting
Derivative time
60
Control
(D) setting
Alert set value 1
0
Control
Alert set value 2
0
Control
Alert set value 3
0
Control
Alert set value 4
0
Control
Temperature
0
Control
process value
(PV) for input
with another
analog module
System area
30
Control
Memory's PID
0
Control
constants read
command
Appendix 3 Buffer Memory Areas
(1)
(2)
(3)
(4)
(5)
A
APPX
173