Mitsubishi Electric MELSEC iQ-R Series User Manual page 196

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
86(56H)
CH2
Direct/reverse
action setting
87(57H)
CH2
Upper limit setting limiter
88(58H)
CH2
Lower limit setting limiter
89(59H)
System area
90(5AH)
CH2
Heater disconnection alert setting
91(5BH)
CH2
Loop
disconnection
detection
judgment time
92(5CH)
CH2
Loop
disconnection
detection dead
band
93(5DH)
CH2
Unused channel setting
94(5EH)
CH2
Memory's PID constants read
command
95(5FH)
CH2
Automatic backup setting after auto
tuning of PID constants
96(60H)
CH3
Input range
97(61H)
CH3
Stop mode
setting
98(62H)
CH3
Set value (SV)
setting
99(63H)
CH3
Proportional
band (P) setting
100(64H)
CH3
Integral time (I)
setting
101(65H)
CH3
Derivative time
(D) setting
102(66H)
CH3
Alert set value 1
103(67H)
CH3
Alert set value 2
104(68H)
CH3
Alert set value 3
105(69H)
CH3
Alert set value 4
106(6AH)
CH3
Upper limit
output limiter
107(6BH)
CH3
Lower limit
output limiter
108(6CH)
CH3
Output variation
amount limiter
109(6DH)
CH3
Sensor correction value setting
APPX
194
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
System area
Upper limit
*3
setting limiter
Lower limit
*3
setting limiter
*11
System area
System area
System area
Unused channel
*3
setting
Memory's PID
constants read
*3
command
Automatic
backup setting
after auto tuning
of PID
*3
constants
Stop mode
Stop mode
*1
setting
setting
Set value (SV)
Set value (SV)
*1
setting
setting
Heating
Proportional
proportional
band (P) setting
band (Ph)
*1
setting
Integral time (I)
Integral time (I)
*1
setting
setting
Derivative time
Derivative time
*1
(D) setting
(D) setting
Alert set value
Alert set value 1
*1
1
Alert set value
Alert set value 2
*1
2
Alert set value
Alert set value 3
*1
3
Alert set value
Alert set value 4
*1
4
Heating upper
Upper limit
limit output
output limiter
*1
limiter
System area
Lower limit
output limiter
Output variation
Output variation
*1
amount limiter
amount limiter
Default
value
Position-
proportional
control
Direct/reverse
1
action setting
Upper limit
1300(TCTRT
setting limiter
)
6000(TCRT)
Lower limit
0(TCTRT)
setting limiter
-2000(TCRT)
0
480
0
Unused channel
0
setting
Memory's PID
0
constants read
command
Automatic
0
backup setting
after auto tuning
of PID constants
2(TCTRT)
7(TCRT)
Stop mode
1
*5
setting
Set value (SV)
0
*5
setting
Proportional
30
band (P)
*5
setting
Integral time (I)
240
*5
setting
Derivative time
60
*5
(D) setting
Alert set value
0
*5
1
Alert set value
0
*5
2
Alert set value
0
*5
3
Alert set value
0
*5
4
System area
1000
System area
0
System area
0
0
Data
(1)
(2)
(3)
(4)
type
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents