Mitsubishi Electric MELSEC iQ-R Series User Manual page 192

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

*1 Enabled only when the R60TCTRT2TT2 or R60TCTRT2TT2BW is used.
*2 This setting differs depending on whether 'Setting variation rate limiter setting selection' (Un\G303) is set to Individually set at
temperature rise/temperature drop (1).
*3 Enabled only when 'Setting variation rate limiter setting selection' (Un\G303) has been set to Individually set at temperature rise/
temperature drop (1).
*4 Enabled only when 'Control mode selection' (Un\G300) has been set to Heating-cooling control (expanded mode) (2). When
Heatingcooling control (normal mode) (2) is set, this area becomes a system area.
*5 Enabled only when 'Control mode selection' (Un\G300) has been set to Heating-cooling control (normal mode) (1). When
Heatingcooling control (expanded mode) (1) is set, this area becomes a system area.
*6 Enabled only when 'Control mode selection' (Un\G300) has been set to Mix control (expanded mode) (4). When Mix control (normal
mode) (3) is set, this area becomes a system area.
*7 Enabled only when 'Control mode selection' (Un\G300) has been set to Mix control (normal mode) (3). When Mix control (expanded
mode) (4) is set, this area becomes a system area.
*8 Enabled only when 'Control mode selection' (Un\G300) has been set to Position-proportional control (expanded mode) (6). When
Position-proportional control (normal mode) (5) is set, this area becomes a system area.
*9 Enabled only when 'Control mode selection' (Un\G300) has been set to Position-proportional control (normal mode) (5). When
Positionproportional control (expanded mode) (6) is set, this area becomes a system area.
*10 [n] in this table indicates an interrupt setting value. (n = 1 to 16)
*11 This value is displayed only in the master module of the inter-module simultaneous temperature rise function. When multiple master
modules have been set, 0 is stored in this area.
*12 This value is displayed only in the master module of the inter-module peak current suppression function. When multiple master modules
have been set, 0 is stored in this area.
*13 Enabled only when the R60TCTRT2TT2BW or R60TCRT4BW is used.
*14 When the control output cycle unit selection setting is 1s cycle
*15 When the control output cycle unit selection setting is 0.1s cycle
APPX
190
Appendix 3 Buffer Memory Areas