Mitsubishi Electric MELSEC iQ-R Series User Manual page 174

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
554(22AH)
CH1
Simultaneous
temperature rise
gradient data
555(22BH)
CH1
Simultaneous
temperature rise
dead time
556(22CH)
CH1
Simultaneous
temperature rise
AT mode
selection
557(22DH)
CH1
Disturbance judgment position
558(22EH)
CH1
Set value return adjustment
559(22FH)
CH1
Feed forward control forced starting signal
560(230H)
CH1
Feed forward value
561(231H)
CH1
Feed forward value tuning selection
562(232H)
CH1
Overshoot suppression level setting
563(233H)
CH1
Primary delay digital filter setting
564(234H)
CH1
Sensor correction function selection
565(235H)
CH1
Sensor correction value setting
566(236H)
CH1
Sensor two-point correction offset latch request
567(237H)
CH1
Sensor two-point correction gain latch request
568(238H)
CH1
Sensor two-point correction offset value (measured value)
569(239H)
CH1
Sensor two-point correction offset value (corrected value)
570(23AH)
CH1
Sensor two-point correction gain value (measured value)
571(23BH)
CH1
Sensor two-point correction gain value (corrected value)
572(23CH)
CH1
Number of moving averaging setting
573 to 599
System area
(23DH to
257H)
600(258H)
CH2
Decimal point position
601(259H)
CH2
Alert definition
602(25AH)
CH2
Temperature process value (PV)
603(25BH)
CH2
Manipulated
value (MV)
604(25CH)
CH2
Temperature rise judgment flag
605(25DH)
CH2
Transistor output
flag
606(25EH)
CH2
Set value (SV) monitor
607(25FH)
CH2
Manipulated
value (MV) for
output with
another analog
module
608(260H)
CH2
System area
609(261H)
CH2
System area
APPX
172
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
System area
System area
System area
Manipulated
Manipulated
value for heating
value for heating
*6
(MVh)
(MVh)
Temperature rise
*6
judgment flag
Heating
Heating
transistor output
transistor output
*6
flag
flag
Set value (SV)
*6
monitor
Manipulated
Manipulated
value for heating
value for heating
(MVh) for output
(MVh) for output
with another
with another
analog module
analog module
Manipulated
Manipulated
value for cooling
value for cooling
*6
(MVc)
(MVc)
Manipulated
Manipulated
value for cooling
value for cooling
(MVc) for output
(MVc) for output
with another
with another
analog module
analog module
Default
value
Position-
proportional
control
0
0
0
System area
0
System area
0
System area
0
System area
0
System area
0
0
0
0
0
0
0
0
0
0
0
2
0(TCTRT)
1(TCRT)
0
0
System area
0
Temperature rise
0
judgment flag
Open side
0
transistor output
flag
Set value (SV)
0
monitor
System area
0
*6
System area
0
System area
0
*6
Data
(1)
(2)
(3)
(4)
type
Setting
Setting
System
area
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents