Mitsubishi Electric MELSEC iQ-R Series User Manual page 212

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
1352(548H)
All
Inter-module
simultaneous
temperature rise
function master/
slave selection
monitor
1353(549H)
All
Number of slave
modules with
inter-module
simultaneous
temperature rise
function
enabled
1354 to 1416
All
Start I/O of slave
(54AH to
module with
588H)
inter-module
simultaneous
temperature rise
function
enabled
1417(589H)
All
Feed forward value read completion flag
1418 to 1449
System area
(58AH to
5A9H)
1450(5AAH)
CH1
Feed forward control forced start status
1451(5ABH)
CH2
Feed forward control forced start
status
1452(5ACH)
CH3
Feed forward
control forced
start status
1453(5ADH)
CH4
Feed forward
control forced
start status
1454(5AEH)
CH1
Feed forward value tuning flag
1455(5AFH)
CH2
Feed forward value tuning flag
1456(5B0H)
CH3
Feed forward
value tuning flag
1457(5B1H)
CH4
Feed forward
value tuning flag
1458(5B2H)
CH1
Feed forward control READY flag
1459(5B3H)
CH2
Feed forward control READY flag
1460(5B4H)
CH3
Feed forward
control READY
flag
1461(5B5H)
CH4
Feed forward
control READY
flag
1462(5B6H)
CH1
Feed forward control forced start READY flag
1463(5B7H)
CH2
Feed forward control forced start
READY flag
APPX
210
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
System area
Inter-module
simultaneous
temperature rise
function master/
slave selection
monitor
System area
Number of slave
modules with
inter-module
simultaneous
temperature rise
function
*8
enabled
System area
Start I/O of slave
module with
inter-module
simultaneous
temperature rise
function
*8
enabled
Feed forward
control forced
start status
Feed forward
Feed forward
control forced
control forced
*1
start status
start status
Feed forward
Feed forward
control forced
control forced
*1
start status
start status
Feed forward
value tuning
flag
Feed forward
Feed forward
value tuning
value tuning flag
*1
flag
Feed forward
Feed forward
value tuning
value tuning flag
*1
flag
Feed forward
control READY
flag
Feed forward
Feed forward
control READY
control READY
*1
flag
flag
Feed forward
Feed forward
control READY
control READY
*1
flag
flag
Feed forward
control forced
start READY
flag
Position-
proportional
control
System area
System area
*8
System area
*8
System area
System area
System area
*3
System area
System area
System area
System area
*3
System area
System area
System area
System area
*3
System area
System area
System area
System area
*3
Default
Data
(1)
(2)
value
type
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
(3)
(4)
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents