Mitsubishi Electric MELSEC iQ-R Series User Manual page 177

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
720(2D0H)
CH2
System area
721(2D1H)
CH2
System area
722(2D2H)
CH2
System area
723(2D3H)
CH2
System area
724(2D4H)
CH2
System area
725(2D5H)
CH2
Derivative action selection
726(2D6H)
CH2
Setting variation rate limiter unit time
setting
727(2D7H)
CH2
System area
728(2D8H)
CH2
System area
729(2D9H)
CH2
System area
730(2DAH)
CH2
System area
731(2DBH)
CH2
Alert dead band setting
732(2DCH)
CH2
Number of alert delay
733(2DDH)
CH2
Alert 1 mode setting
734(2DEH)
CH2
Alert 2 mode setting
735(2DFH)
CH2
Alert 3 mode setting
736(2E0H)
CH2
Alert 4 mode setting
737(2E1H)
CH2
Loop
disconnection
detection
judgment time
738(2E2H)
CH2
Loop
disconnection
detection dead
band
739(2E3H)
CH2
Rate alarm alert output enable/disable setting
740(2E4H)
CH2
Rate alarm alert detection cycle
741(2E5H)
CH2
Rate alarm upper limit value
742(2E6H)
CH2
Rate alarm lower limit value
743(2E7H)
CH2
Auto tuning mode selection
744(2E8H)
CH2
Auto tuning error judgment time
Heating-
Mix control
cooling
control
Temperature
conversion
*7
setting
Cooling upper
Cooling upper
limit output
limit output
*6
limiter
limiter
Cooling control
Cooling control
output cycle
output cycle
*6
setting
setting
Cooling method
Cooling method
*6
setting
setting
Overlap/dead
Overlap/dead
*6
band setting
band setting
Derivative action
*6
selection
Setting variation
rate limiter unit
*6
time setting
Alert dead band
*6
setting
Number of alert
*6
delay
Alert 1 mode
*6
setting
Alert 2 mode
*6
setting
Alert 3 mode
*6
setting
Alert 4 mode
*6
setting
System area
System area
Auto tuning
*6
mode selection
Auto tuning error
*6
judgment time
Default
Data
value
type
Position-
proportional
control
System area
0
Setting
System area
1000
Setting
*14
System area
30
Setting
*15
300
System area
0
Setting
System area
0
Setting
System area
0
Setting
Setting variation
0
Setting
rate limiter unit
time setting
Open/close
20
Setting
output neutral
band setting
Control motor
10
Setting
time
Integration
1500
Setting
output limiter
setting
Valve operation
0
Setting
setting during
CPU module
STOP
Alert dead band
5
Setting
setting
Number of alert
0
Setting
delay
Alert 1 mode
0
Setting
setting
Alert 2 mode
0
Setting
setting
Alert 3 mode
0
Setting
setting
Alert 4 mode
0
Setting
setting
480
Setting
0
Setting
1
Setting
1
Setting
0
Setting
0
Setting
Auto tuning
0
Setting
mode selection
Auto tuning error
120
Setting
judgment time
Appendix 3 Buffer Memory Areas
(1)
(2)
(3)
(4)
(5)
A
APPX
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents