RELEVANT MANUALS

Manual name [manual number]
MELSEC iQ-R Temperature Control Module User's
Manual (Application)
[SH-081536ENG] (this manual)
MELSEC iQ-R Temperature Control Module User's
Manual (Startup)
[SH-081535ENG]
MELSEC iQ-R Module Configuration Manual
[SH-081262ENG]
MELSEC iQ-R Temperature Control Module
Function Block Reference
[BCN-P5999-0565]
GX Works3 Operating Manual
[SH-081215ENG]
e-Manual refers to the Mitsubishi Electric FA electronic book manuals that can be browsed using a dedicated
tool.
e-Manual has the following features:
• Required information can be cross-searched in multiple manuals.
• Other manuals can be accessed from the links in the manual.
• Hardware specifications of each part can be found from the product figures.
• Pages that users often browse can be bookmarked.
• Sample programs can be copied to an engineering tool.

TERMS

Unless otherwise specified, this manual uses the following terms.
Term
AT point
Buffer memory
Control method
Control mode
CPU module
Engineering tool
Master/local module
PID constants
Q compatible mode
R mode
Redundant system with redundant
extension base unit
Remote head module
Simultaneous temperature rise
parameter
14
Description
Functions, parameter settings, troubleshooting, I/O signals, and buffer memory
of the temperature control module
Specifications, procedures before operation, wiring, and operation examples of
the temperature control module
The combination of the MELSEC iQ-R series modules, common information
on the installation/wiring in the system, and specifications of the power supply
module, base unit, SD memory card, and battery
FBs of a Temperature control module
System configurations, parameter settings, and operation methods for the
online function in GX Works3
Description
The total of Set value (SV) setting and AT bias
The intelligent function module's memory where the data (including setting values and monitored values) received/sent
from/to the CPU module is stored
The generic term of two-position control, P control, PI control, PD control, and PID control
The generic term of standard control, heating-cooling control (normal mode), heating-cooling control (expanded mode),
mix control (normal mode), mix control (expanded mode), position proportional control (normal mode), and position
proportional control (expanded mode)
The generic term of MELSEC iQ-R series CPU modules
The product name of the MELSEC programmable controller software package
The generic term of following modules of when an RJ71GF11-T2 CC-Link IE Field Network master/local module and a
CC-Link IE Field Network function are used
• RJ71EN71
• RnENCPU
The generic term of the proportional band (P), integral time (I), and derivative time (D)
In this mode, the buffer memory map is converted into the one for the MELSEC-Q series and the module operates with
the buffer memory map.
In this mode, the module operates with the buffer memory map that has been newly assigned for the MELSEC iQ-R
series.
A redundant system that is configured using extension base unit(s)
The abbreviation for the RJ72GF15-T2 CC-Link IE Field Network remote head module
The generic term of simultaneous temperature rise dead time and simultaneous temperature rise gradient data