Chapter 15 Remote Management Configuration

15.1.1 Remote Management Limitations

Remote management over LAN or WAN will not work when:
• You have disabled that service in one of the remote management screens.
• The IP address in the Secured Client IP field does not match the client IP address. If it
does not match, the ZyXEL Device will disconnect the session immediately.
• There is already another remote management session with an equal or higher priority
running. You may only have one remote management session running at one time.
• There is a firewall rule that blocks it.

15.1.2 Remote Management and NAT

When NAT is enabled:
• Use the ZyXEL Device's WAN IP address when configuring from the WAN.
• Use the ZyXEL Device's LAN IP address when configuring from the LAN.

15.1.3 System Timeout

There is a system management idle timeout. The ZyXEL Device automatically logs you out if
the management session remains idle for longer than this timeout period. The management
session does not time out when a statistics screen is polling. The default value is five minutes,
and you can change or disable this in

15.2 WWW

Use this screen to change your ZyXEL Device's World Wide Web settings. Click Advanced
> Remote MGMT to display the WWW screen.
Figure 99 Remote MGMT > WWW
The following table describes the labels in this screen.
Table 71 Remote MGMT > WWW
LABEL
Port
Access Status
196
Section 17.1.2 on page
DESCRIPTION
You may change the server port number for a service if needed, however you must
use the same port number in order to use that service for remote management.
Select the interface(s) through which a computer may access the ZyXEL Device
using this service.
219.
P-793H User's Guide