inverters
Goodrive300
Note: If fault occurs, please do as the "Fault Tracking". Esitimate the fault reason and settle the
issue.
Besides P00.01 and P00.02, terminal command setting can also used to set the running command
channel.
Current runnig
command channel
P00.01
Keypad runnig
command channel
Terminal runnig
command channel
Communication
runnig command
channel
Note: "/" means the multi-function terminal is invalid on the current given channel.
Relative parameters table:
Function
code
P00.00
Speed control mode
P00.01
Run command channel
Communication running
P00.02
Multi-function terminal
36
Switch to keypad
/
Keypad runnig
command channel
Keypad runnig
command channel
Name
commands
Multi-function
terminal 37
Switch to to terminal
Terminal runnig
command channel
/
Terminal runnig
command channel
Detailed instruction of parameters
0: Sensorless vector control mode 0
(apply to AM and SM)
1: Sensorless vector control mode 1
(applying to AM)
2:V/F control
0:Keypad running command
1:Terminal running command channel
("LOCAL/REMOT" flickering)
2:Communication running command
channel ("LOCAL/REMOT" on);
0:MODBUS communication channel
1: PROFIBUS\CANopen communication
channel
148
Basic operation instruction
Multi-function terminal
38
Switch to to
communication
Communication
runnig command
channel
Communication
runnig command
channel
/
Default
value
1
0
0
Need help?
Do you have a question about the Goodrive 300 and is the answer not in the manual?
Questions and answers