INVT Goodrive 300 Operation Manual page 110

Hide thumbs Also See for Goodrive 300:
Table of Contents

Advertisement

inverters
Goodrive300
Functi
on
Name
code
arrival
detection
value
Energy
P08.37
braking
enable
Threshold
P08.38
voltage
Cooling fan
P08.39
running
mode
Detailed instruction of parameters
or negative detection range of the set frequency,
the multi-function digital output terminal will output
the signal of "frequency arrival", see the diagram
below for detailed information:
The setting range:0.00Hz~P00.03(the Max.
frequency)
This parameter is used to control the internal
braking pipe inside the inverter.
0:Disable
1:Enable
Note: Only applied to internal braking pipe.
After setting the original bus voltage to brake the
energy, adjust the voltage appropriately to brake
the load. The factory changes with the voltage
level.
The setting range:200.0~2000.0V
0: Normal mode
1:The fan keeps running after power on
109
Function codes
Default
Modif
value
y
0
220V
voltage:
380.0V
380V
voltage:
700.0V
660V
voltage:
1120.0V
0

Hide quick links: