6
Descriptions of each function
6.6 Scanner abnormality monitoring function (Yaskawa head only)
6.6. Scanner abnormality monitoring function (Yaskawa head only)
* This function is available when using the remote laser with a Yaskawa Control head.
This function monitors errors from the galvano driver for the head so that the system can
issue alarms. It also monitors the deviation between the motor feedback pulse from the
galvano driver and the command pulse; it issues an error if there is an abnormal
deviation. This function can be controlled with the following S1E parameters.
Parameter
Name
X-axis feedback pulse
monitoring conditions
S1E236
Y-axis feedback pulse
monitoring conditions
S1E237
Z-axis feedback pulse
monitoring conditions
S1E238
Alarm OFF bit
S1E239
Details
Specifies the upper limit for the
deviation between the feedback
pulse and the pulse command as
well as the acceptable value for the
number of successive attempts to
exceed the upper limit.
Top byte:
Upper limit of deviation (unit: 256
pulses)
Bottom byte:
Number of successive attempts to
exceed the limit (unit: times)
Example of the upper limit of
deviation: 1,024 pulses; number of
successive attempts to exceed the
limit: 5 times
Top byte: 4, bottom byte: 5
0x0405
1029 (decimal)
Turn OFF individual scanner
alarms.
(Alarm OFF for raised bits)
d0: Thermostat 1
d1: Thermostat 2
d2: X-axis
d3: Y-axis
d4: Z-axis
6-65
Default
50
(4,000 pulses
when the top
is 0)
50
(4,000 pulses
when the top
is 0)
50
(4,000 pulses
when the top
is 0)
0
(all ON)
HW1486273
Unit
-
-
-
-