4
Remote laser welding condition registration files

4.7 Adding paths

4.7. Adding paths
(1) To add a new path before the path displayed in the
remote laser record conditions window, select {EDIT}
 {INSERT PATH}.
(2) A dialog box will appear with the message,
"Welding path is inserted. OK?" Click {YES}.
(3) A new path will be added before the path
displayed.
* Because 15 paths can be registered per remote
laser record conditions file, adding a new path deletes
the condition data in the 15th path.
4-47