Testing The Switch Fabric And Address Resolution Table - Avaya 8800 Troubleshooting Manual

Ethernet routing switch
Table of Contents

Advertisement

Software troubleshooting tool configuration using Enterprise Device Manager
6. Click Insert.
7. Configure the filter as required.
8. Select Pcap.
9. Click Insert.

Testing the switch fabric and address resolution table

You can use the Diagnostics Test tab in Enterprise Device Manager to perform two tests. You
can test the switch fabric and check the address resolution (AR) table for consistency.
The fabric test causes the CPU to generate traffic and send it through the switch fabric. The
CPU generates little traffic.
The AR table test performs a consistency check on address resolution table entries.
Procedure steps
1. In the navigation tree, open the following folders Configuration > Edit >
2. Click General.
3. To test the Address Resolution table, click AR Test.
4. To test the switch fabric, click Fabric.
Variable definitions
Use the information in the following table to understand the test parameters.
Result
Code
94
Troubleshooting
Diagnostics.
The test runs; PassCount and FailCount are updated. Use the Stop button to stop
in-progress tests.
The test runs; PassCount and FailCount are updated. Use the Stop button to stop
in-progress tests.
Variable
Comments? infodev@avaya.com
The result of the most recently run (or current) test:
none, success, inProgress, notSupported,
unAbleToRun, aborted, failed.
More specific information about the test result (for
example, an error code after a failed test): none,
NoReceive (timeout on a send), BadSeq (packets
received out of sequence), BadLen (packet length
mismatch), BadData (packet data mismatch)
Value