Z-Phase Pulse Output - Mitsubishi Electric MELSERVO-J5 MR-J5 Series User Manual

Hide thumbs Also See for MELSERVO-J5 MR-J5 Series:
Table of Contents

Advertisement

Z-phase pulse output

Z-phase pulse output specifications
The Z-phase pulse is outputted by each encoder as follows.
Encoder type
Linear encoders
Incremental
Absolute position
A/B/Z-phase differential output encoder
Z-phase pulse output width
The minimum pulse width of the Z-phase pulse output is about 400 μs.
Z-phase pulse output
Outputs one pulse every time the Z-phase of the linear encoder is passed.
Outputs one pulse for every virtual rotation.
Outputs one pulse every time the Z-phase of the scale is passed.
4 APPLICABLE FUNCTIONS
4.13 A/B/Z-phase pulse output function
4
279