Setting functional safety parameters
Refer to the following to set the functional safety parameters.
Page 327 Functional safety parameters that must be set
When using the safety sub-function control by input device, refer to the following.
Page 331 Input device
When using output devices, refer to the following.
Page 334 Output device
When using the safety sub-function control by network, refer to the following.
Page 337 Safety sub-function control by network
When using the SLT function, set the following parameters.
Parameter
PSB10
PSB11
PSB12
PSB13
PSB14
PSB15
PSB16
PSB17
PSB18
■SLT torque 1 to SLT torque 4
Refer to the operation sequence and set the threshold for torque monitoring. Although there are parameters corresponding to
SLT1C (SLT1 command) to SLT4C (SLT4 command), it is not necessary to set the parameters corresponding to commands
that are not enabled.
■SLT torque detection delay time
Set the error detection time for the detected torque. The setting value of this parameter changes the delay time from when the
SLT torque exceeds during torque monitoring to when the STO function is activated.
6 FUNCTIONAL SAFETY
372
6.4 Safety sub-function
Name
SLT torque upper limit value 1
SLT torque upper limit value 2
SLT torque upper limit value 3
SLT torque upper limit value 4
SLT torque lower limit value 1
SLT torque lower limit value 2
SLT torque lower limit value 3
SLT torque lower limit value 4
SLT torque detection delay time