3.20

Halt [G] [WG]

Halt defined in CiA 402 enables temporary stop of the servo motor.
When 1 is set in Bit 8 (HALT) of [Controlword (Obj. 6040h)], the servo motor decelerates to a stop with the deceleration time
constant of [Profile deceleration (Obj. 6084h)] or [Homing acceleration (Obj. 609Ah)], and then the state remains as
"Operation Enable" (Servo-on), in accordance with the setting of [Halt option code (Obj. 605Dh)]. When Halt Bit is set to 0
during the deceleration stop operation, the servo motor decelerates to a stop and returns to the operable state.
• This function can be used in the profile mode (pp/pv/tq) and homing mode (hm). The other control modes
can be operated regardless of the Halt Bit status.
• In the profile torque mode (tq), [Torque demand value (Obj. 6074h)] is set to 0 regardless of [Halt option
code (Obj. 605Dh)]. The amount of torque change at this time can be set using [Torque slope (Obj. 6087h)].

Objects for setting

For details on the objects, refer to the User's Manual (Object Dictionary).
Index
Sub
605Dh
*1
6084h
609Ah
*1 Available on servo amplifiers with firmware version A5 or later.
The following table shows descriptions of [Halt option code (Obj. 605Dh)].
Setting value
Description
1
The servo motor decelerates to a stop in accordance with [Profile deceleration (Obj. 6084h)] during the profile mode (pp/pv) and in
accordance with [Homing acceleration (Obj. 609Ah)] during the homing mode (hm), and the servo motor remains as "Operation Enabled
(servo-on)".
2
After deceleration to a stop in accordance with [Quick stop deceleration (Obj. 6085h)], the state remains as "Operation Enabled". (Servo-
(not currently
on is maintained.)
supported)
3
After deceleration to a stop by limiting the current, the state remains as "Operation Enabled". (Servo-on is maintained.)
(not supported)
4
After deceleration to a stop by limiting the voltage, the state remains as "Operation Enabled". (Servo-on is maintained.)
(not supported)

Timing chart

Servo motor speed
HALT
([Controlword
(Obj. 6040h)] bit 8)
3 BASIC FUNCTION
146
3.20 Halt [G] [WG]
Object
Name
VAR
Halt option code
VAR
Profile deceleration
VAR
Homing acceleration
Deceleration time
set with Halt option
code
Description
Setting for executing the Halt function
Refer to the following table for the description.
Deceleration at arrival to target position (acc units)
Acceleration/deceleration time constant at homing (acc units)
t