Standard Acquisition Waveform List [A] - Mitsubishi Electric MELSERVO-J5 MR-J5 Series User Manual

Hide thumbs Also See for MELSERVO-J5 MR-J5 Series:
Table of Contents

Advertisement

Standard acquisition waveform list [A]

When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the acquired data is
changed by [Pr. PA23 Drive recorder desired alarm trigger setting]. If [Pr. PA23] is set to the initial value (00000000h), the data
shown in the "Standard" section of the following table is saved. If the alarm numbers described in the following table are set
with [Pr. PA23], the data in each alarm number section will be saved.
Measurement data with "+" added to the name refers to data with an extended measurement data range and units.
Trigger
Data 1
condition
Standard
Servo
motor
speed +
SON
AL. 010
Servo
motor
speed +
SON
AL. 020
Servo
motor
speed +
SON
AL. 021
Servo
motor
speed +
SON
AL. 024
Servo
motor
speed +
SON
AL. 030
Servo
motor
speed +
SON
AL. 031
Servo
motor
speed +
SON
AL. 032
Servo
motor
speed +
SON
AL. 033
Servo
motor
speed +
SON
AL. 035
Servo
motor
speed +
SON
4 APPLICABLE FUNCTIONS
256
4.6 Drive recorder
Data 2
Data 3
Data 4
Torque
Current
Droop
command
pulses (1
pulse) +
EM2/
ALM2
INP
EM1
Torque
Current
Droop
command
pulses (1
pulse) +
EM2/
ALM2
INP
EM1
Torque
ABS
Position
counter
within one-
revolution
EM2/
ALM2
INP
EM1
Torque
ABS
Position
counter
within one-
revolution
EM2/
ALM2
INP
EM1
Torque
Current
Position
command
within one-
revolution
EM2/
ALM2
INP
EM1
Torque
Current
Droop
command
pulses (1
pulse) +
EM2/
ALM2
INP
EM1
Torque
Current
Command
command
pulse
frequency +
EM2/
ALM2
INP
EM1
Torque
Current
Bus voltage
command
EM2/
ALM2
INP
EM1
Torque
Current
Speed
command
command +
EM2/
ALM2
INP
EM1
Torque
Current
Command
command
pulse
frequency +
EM2/
ALM2
INP
EM1
Data 5
Data 6
Data 7
Speed
Bus voltage
Effective
command +
load ratio
MBR
RD
STO
Speed
Bus voltage
Effective
command +
load ratio
MBR
RD
STO
Current
Encoder error
Encoder
command
counter 1
error
counter 2
MBR
RD
STO
Current
Encoder error
Encoder
command
counter 1
error
counter 2
MBR
RD
STO
Bus voltage
U-phase
V-phase
current
current
feedback
feedback
MBR
RD
STO
Bus voltage
Regenerative
Effective
load ratio
load ratio
MBR
RD
STO
Position
Speed
Bus voltage
within one-
command +
revolution
MBR
RD
STO
Effective
U-phase
V-phase
load ratio
current
current
feedback
feedback
MBR
RD
STO
Bus voltage
Regenerative
Effective
load ratio
load ratio
MBR
RD
STO
Droop
Speed
Bus voltage
pulses (1
command
pulse) +
MBR
RD
STO
Data 8 Sampling
Measurement
cycle
time
0.500 ms
512 ms
IPF
0.500 ms
512 ms
IPF
0.500 ms
512 ms
IPF
0.500 ms
512 ms
IPF
0.500 ms
512 ms
IPF
32 ms
32768 ms
IPF
0.500 ms
512 ms
IPF
0.250 ms
256 ms
IPF
2 ms
2048 ms
IPF
0.500 ms
512 ms
IPF