Limit Switch Release Position Assessment Function [G] [Wg]; Outline; Precautions; Setting Methods Of Functions - Mitsubishi Electric MELSERVO-J5 MR-J5 Series User Manual

Hide thumbs Also See for MELSERVO-J5 MR-J5 Series:
Table of Contents

Advertisement

3.6
Limit switch release position assessment function
[G] [WG]

Outline

The limit switch release position assessment function is available on servo amplifiers with firmware version B2 or later.
This function can be used in the cyclic synchronous position mode (csp) or cyclic synchronous velocity mode (csv).
Use this function in the following cases: After the limit switch has been detected, the moving part passes through the limit
switch detection position and stops. If the moving part passes through the limit switch detection position and stops, commands
in the direction where the moving part has moved cannot be accepted until the warning release conditions are met.
Limit switch
LSP
(Forward rotation stroke end)
LSN
(Reverse rotation stroke end)
[AL. 099 Stroke limit warning]
Rotation enabled direction
*1 Page 98 Precautions

Precautions

Check that the moving part is currently located in the area between the limit switches before operation. This function cannot
work properly in the following situations:
• Turning on the power while the moving part is outside the area between the limit switches.
• Resetting the controller while the moving part is outside the area between the limit switches.
• Performing homing while the moving part is outside the area between the limit switches.
• Switching the control mode while the moving part is outside the area between the limit switches.
• The limit switches are on for less than 10 ms.

Setting methods of functions

[Pr. PT38.4 Limit switch release position assessment function selection] can be used to select whether [AL. 099 Stroke limit
warning] is released without or after a limit position assessment. The stroke limit warning will be released after all the release
conditions have been met.
[Pr. PT38.4]
0
1
Limit position assessment
When the moving part returns to the position where the stroke end was detected, the warning release conditions will be met.
3 BASIC FUNCTION
98

3.6 Limit switch release position assessment function [G] [WG]

LSN
ON
OFF
(Enabled)
ON
OFF
(Enabled)
Warning
occurrence
Forward rotation
command available
rotation command available
*1
Stops upon limit switch detection
LSP
Warning
No warning
occurrence
Forward/reverse
Reverse rotation
command available
*1
Limit switch release position assessment function
Disabled
Enabled
Maintain [AL. 099 Stroke limit warning]
with LSP/LSN turned on.