Method of reading recorded data
Drive recorder data can be read with an engineering tool (MR Configurator2) via a network or USB connection.
A connection example is shown below.
• Transferring files with direct connection or via a hub (Ethernet/MR Configurator2)
Servo amplifier
Drive recorder
data
• Transferring files with direct connection (USB/MR Configurator2)
Servo amplifier
Drive recorder
data
• Transferring files with direct connection or via a hub (Ethernet/GX LogViewer)
To read recorded data from the drive recorder by using the FTP server function, use a network supporting the function.
Servo amplifier
Drive recorder
data
Ethernet hub
Ethernet cable
USB cable
Ethernet hub
Ethernet cable
FTP server
Ethernet cable
Ethernet cable
FTP client
Log file
Personal computer
Engineering tool
MR Configurator2
Personal computer
Engineering tool
MR Configurator2
Personal computer
Engineering tool
GX LogViewer
4 APPLICABLE FUNCTIONS
4.6 Drive recorder
4
237