Mitsubishi Electric MELSERVO-J5 MR-J5 Series User Manual page 224

Hide thumbs Also See for MELSERVO-J5 MR-J5 Series:
Table of Contents

Advertisement

■Related objects
The following is a description of objects related to the static friction failure prediction function.
For details on the objects, refer to the User's Manual (Object Dictionary).
Index
Sub
2C29h
0
2C33h
0
2C34h
0
2C35h
0
4 APPLICABLE FUNCTIONS
222
4.5 Machine diagnosis
Object
Name
VAR
Fault prediction status
VAR
Static frictionbased fault
prediction upper threshold
VAR
Static friction based fault
prediction lower threshold
VAR
Static friction based fault
prediction prepare status
Description
[Bit 0 to 3: Friction failure prediction status]
0: Friction failure prediction disabled
1: During preparation for friction failure prediction
2: During execution of friction failure prediction
3: During friction failure prediction warning
[Bit 4 to 7: Vibration failure prediction status]
0: Vibration failure prediction disabled
1: During preparation for vibration failure prediction
2: During execution of vibration failure prediction
3: During vibration failure prediction warning
[Bit 8 to 11: Total travel distance failure prediction status]
0: Motor total travel distance failure prediction disabled
1: Motor total travel distance failure prediction being executed
2: Motor total travel distance failure prediction at warning
[Bit 12 to 15: Motor total travel distance calculation status]
0: During stop of motor total travel distance calculation
1: During calculation of motor total travel distance
[Bit 16 to 19: reserved]
[Bit 20 to 23: Static friction failure prediction status]
0: Static friction failure prediction disabled
1: During preparation for static friction failure prediction
2: During execution of static friction failure prediction
3: During static friction failure prediction warning
[Bit 24 to 27: Belt tension deterioration prediction status]
0: Belt tension deterioration prediction disabled
1: Belt tension deterioration prediction in progress
2: During belt tension deterioration warning
[Bit 28 to 31: Belt tension estimation status]
0: Belt tension estimation in progress
1: Belt tension estimation has finished
7: Belt tension estimation is not set
The upper limit threshold used for static friction failure prediction is
displayed in increments of 0.1 % in relation to the rated torque as 100
%.
The lower limit threshold used for static friction failure prediction is
displayed in increments of 0.1 % in relation to the rated torque as 100
%.
The creation progress of the thresholds used in static friction failure
prediction is displayed as a percentage. Creation of friction failure
prediction for the upper and lower limit threshold finishes at 100 %.