Figure 4‑17. Communications transaction example

AE HOST COMMANDS

The following sections describe the command status response (CSR) codes returned
by the Paramount MF 2 kW unit in response to a command, as well as the AE Host
commands for the Paramount MF 2 kW unit.

AE Host Command Status Response (CSR) Codes

When the Paramount MF 2 kW unit receives a command requesting a change in unit
operation (commands 1 through 127), or when the Paramount MF 2 kW unit receives
any command that it rejects (commands 1 through 255), it responds with a command
status response (CSR) code. The CSR is a single-byte number that indicates whether
the unit accepted or rejected the command and, in the case of rejection, the reason the
unit could not respond to the command.
Table 4‑9. AE Host command status response (CSR) codes
Code
0
The following CSR codes are sent in response to a command that was not accepted
and provide an indication of why the command was not accepted
1
2
4
5
7
8
57020114-00E
Data
Chksum
ACK
Command accepted
Control mode is incorrect
Output is on (change not allowed)
Command specifies a value that exceeds the limit for that parameter
User port off signal is active.
One or more faults are active.
Set point ramping is active.
Communication Controls
Paramount
Unit
ACK
Header
Cmd
CSR
Time
Meaning
®
MF 2 kW Generator
Chksum
4‑19