Table 4‑10. AE Host commands (Continued)
Command
172
report pulsing
configuration
172
report pulsing mode
(subcommand 1)
172
report pulse sync
output status
(subcommand 2)
57020114-00E
Description
Reports pulsing configuration.
This command allows you to send
subcommands. Send a value in the first two
bytes that selects the parameter to report, and
then send subcommands to report parameter
values.
Byte 0 =
1
Report pulsing mode
(master or slave)
2
Report pulse sync output
status
3
Reserved
4
Reserved
5
Report memory mode
Reports whether the unit is set to master or
slave pulsing mode.
Send 2 data bytes.
• Bytes 0 and 1 = 1 (report pulsing mode)
Returns 4 data bytes.
• Bytes 1 and 2 = Pulsing mode
◦ 1 = Master mode
◦ 2 = Slave mode
• Bytes 2 and 3 = Reserved
Command 26 B0 = 1 sets these values.
Reports the status of pulse sync output.
Send 2 data bytes.
• Bytes 0 and 1 = 2 (report pulse sync
output status)
Returns 4 data bytes.
• Bytes 0 and 1 = Pulse sync output on or
off
◦ 0 = Pulse sync output off
Communication Controls
Paramount
Subcommand
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
2
4
2
4
2
4
4‑52