Advanced Energy Paramount MF 2 kW User Manual page 88

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
215
report real time
clock
219
report condensed
generator snapshot
data
57020114-00E
Description
Returns 4 data bytes (one 32-bit value).
• Bytes 0 through 3 = Total energy output
in kWh
Reports the system real time clock time and
date. The data received is encoded in Binary
Coded Decimal (BCD) format; for example: if
the value for seconds is 48, the data value
received will be 0x48. The real time clock
features automatic leap year compensation for
years up to 2100.
Returns 7 data bytes (8-bit values):
• Byte 0 = Seconds (valid values are 0 to
59)
• Byte 1 = Minutes (valid values are 0 to
59)
• Byte 2 = Hours (valid values are 0 to 23)
• Byte 3 = Day of the week (valid values
are 1 to 7)
◦ 1 = Sunday
◦ 2 = Monday
◦ 3 = Tuesday
◦ 4 = Wednesday
◦ 5 = Thursday
◦ 6 = Friday
◦ 7 = Saturday
• Byte 4 = Date (valid values are 1 to 31)
• Byte 5 = Month (valid values are 1 to 12)
• Byte 6 = Year (valid values are 00 to 99)
Set this value with command 70.
Reports a selected collection of data identical
to the data reported by the individual
commands.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0
0
Data
Bytes
7
28
4‑56