Table 4‑3. 25-pin User port pin descriptions  (Continued)
Signal
Related
Pin
Pin
5
18
6
19
7
8
21
57020114-00E
Name
Signal
Type
SET POINT
Analog
input
DC BIAS/
Digital
POWER
input
REGULATION
FWD/LOAD
Digital
PWR
input
REGULATION
Communication Controls
®
Paramount
MF 2 kW Generator
Description
the RF output. Logic low disables the RF
output in either user control mode or host
control mode.
 Important
The interlocks must be satisfied
and the set point must be within
the output power range before
unit will deliver power.
See
Figure 4‑4
on page 4‑7 for the
wiring diagram.
This pin linearly controls the RF output
of the generator in either forward power
mode or load power mode.
• 0 V to 10 V = 0 W to maximum
rated output power
This input also provides set point in the
voltage control mode.
• 0 V to 10 V = 0 V to 2000 V peak
to peak
See
Figure 4‑5
on page 4‑7 for the
wiring diagram.
This pin switches the regulation mode of
the generator.
When logic low is applied to this pin, or
if there is no connection to this pin, the
generator regulates output power (either
forward or load, as defined by the signal
on pin 8).
When logic high is applied to this pin,
the generator regulates in the voltage
control mode.
See
Figure 4‑6
on page 4‑8 for the
wiring diagram.
Not connected.
Applying logic high to this pin causes
the generator to regulate on load power.
Logic low or no connection to this pin
causes the generator to default to
forward power regulation.
4‑4