Table 4‑10. AE Host commands (Continued)
Command
60
set tune delay
61
set fixed frequency
70
set real time clock
57020114-00E
Description
Sets the time in ms that the tuning algorithm
waits before beginning to tune the generator
automatically. The unit stores this parameter
in nonvolatile memory. You cannot change
this setting while output is on. The maximum
tune delay value is 60,000 ms. The default
value is 50 ms.
Send 2 or 4 data bytes. If the value doesn't fit
into two bytes, it should be sent in four.
• Bytes 0 and 1 = Tune delay time in ms.
Command 160 reports this value.
Sets the generator output frequency when
operating in fixed frequency mode. You can
change the generator frequency while the
output is on when operating in the fixed
frequency mode. The fixed frequency value
must be within the unit frequency range.
For units that allow you to set the fixed
frequency memory mode (see command 118;
B0 = 51), the fixed frequency parameter can
be set to either volatile or nonvolatile.
Some units allow you to retrieve minimum
and maximum fixed frequency settings with
command 161.
Send 4 data bytes to set the value in kHz, or 5
data bytes to set the value in either kHz or Hz.
Send 4 data bytes (32-bit value):
• Frequency in kHz
Send 5 data bytes:
• Byte 0 = kHz or Hz
◦ 0 = Frequency is in kHz
◦ 1 = Frequency is in Hz
• Bytes 1 through 4 = Frequency value
Command 161 reports this value
Sets the system real time clock to the time/
date specified. The data transmitted must be
encoded in BCD (binary coded decimal)
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
2 or 4
4 or 5
7
Data
Bytes
1
1
1
4‑30